Page 1 - User Manual

QTS-CLX-APACS APACS® IOBUS Module User Manual

Page 2

Page 4 QTS-CLX-APACS March 2015 Installation Prevent Electrostatic Discharge The module is sensitive to electrostatic discharge. WARNING! ATTE

Page 3

QTS-CLX-APACS Page 5 You can install multiple QTS-CLX-APACS modules in the same chassis. Insert the Module in the Chassis The ControlLogix module i

Page 4

Page 6 QTS-CLX-APACS March 2015 Figure 2 Inserting the Module Replacing a Module If you are replacing an existing module with an identical one, a

Page 5 - ACCESSING DATA 38

QTS-CLX-APACS Page 7 Cabling and Termination WARNING! Connecting the module disrupts bus traffic! Connect the module at a time when it is safe to do

Page 6 - WARRANTY 47

Page 8 QTS-CLX-APACS March 2015 Configuring the Module in RSLogix 5000 You configure the module in RSLogix 5000 to set how much scheduled data to

Page 7

QTS-CLX-APACS Page 9 2. Place another ENBT on the Ethernet under the first ENBT. Disable keying, set the Rack Connection to None,

Page 8 - Module Features

Page 10 QTS-CLX-APACS March 2015 3. Place generic 1756-MODULEs in slots 0 to 9, as required. The configuration programs assign IO

Page 9 - Package Contents

QTS-CLX-APACS Page 11 Click OK Connection for REAL data Set the Comm Format to Data – REAL Set the Connection Parameters as shown. T

Page 10 - Installation

Page 12 QTS-CLX-APACS March 2015 Connection for Diagnostic Data Diagnostics are always mapped to connection 9. Connection 9 is not required but w

Page 11 - QTS-CLX-APACS Page 5

QTS-CLX-APACS Page 13 For example, you can use a longer RPI for the diagnostic data in connection 9, for example 500 milliseconds, since diagnostics

Page 12 - Replacing a Module

Page ii QTS-CLX-APACS March 2015 Because of the variety of uses for the products described in this publication, those responsible for the applica

Page 13 - Software Installation

Page 14 QTS-CLX-APACS March 2015 RSLinx When you right click on the module in RSLinx and select Properties, RSLinx displays the following: Parame

Page 14 - Module Configuration

QTS-CLX-APACS Page 15 Monitor Mode Operation The following is a short summary of the steps typically followed. Refer to the appropriate manual sect

Page 15 - QTS-CLX-APACS Page 9

Page 16 QTS-CLX-APACS March 2015 Exporting a 4-mation database file The monitor configuration program uses a database file exported from the Sieme

Page 16

QTS-CLX-APACS Page 17 Double click on each module and confirm that the channel types for that module are all present and correct.

Page 17 - QTS-CLX-APACS Page 11

Page 18 QTS-CLX-APACS March 2015 What gets mapped I/O Data APACS IOBUS discrete inputs and outputs are mapped to the input data o

Page 18

QTS-CLX-APACS Page 19 Alias Name Offset Description StatBusANoiseErr 2 Bad packets, network noise StatFrameErr 3 Bad packets, framing errors S

Page 19 - QTS-CLX-APACS Page 13

Page 20 QTS-CLX-APACS March 2015 The QTS-CLX-APACS Module Properties dialog appears. Enter the Module Name. It can be up to 15 characters long.

Page 20

QTS-CLX-APACS Page 21 TIP Use the same name that you assign the second ENBT module associated with the QTS-CLX-APACS in RSLogix 5000 to make it eas

Page 21 - Monitor Mode Operation

Page 22 QTS-CLX-APACS March 2015 Configuring the QTS-CLX-APACS Module in RSLogix 5000. Follow the procedure on page 8 to configure the QTS-CLX-A

Page 22 - Configuring the IOBUS

QTS-CLX-APACS Page 23 Enter the RSLinx Path Specifier to set the location of the module. This will be the name of the second ENBT module associate

Page 24 - What gets mapped

Page 24 QTS-CLX-APACS March 2015 In this example, the module is in rack 1slot 6. The alias is for an analog input from channel 2 on the module, w

Page 25 - Setting the Module Name

QTS-CLX-APACS Page 25 Using Monitor Mode for Migration You can use monitor mode on the QTS-CLX-APACS to migrate existing APACS applications to Contr

Page 26

Page 26 QTS-CLX-APACS March 2015 and the corresponding alias in master mode ALIAS,"","APACS_AO_R01S06C01","APACS_AO_R01S0

Page 27 - Saving a Configuration File

QTS-CLX-APACS Page 27 Master Mode Operation WARNING! Never connect the APACS in master mode to the network while the ACM is controlling I/O. It tr

Page 28 - Aliases

Page 28 QTS-CLX-APACS March 2015 ClxApacsMasCfg Software The QTS-CLX-APACS module is supplied with a Windows configuration tool, ClxApacsMasCfg.ex

Page 29 - QTS-CLX-APACS Page 23

QTS-CLX-APACS Page 29 Double click on each module and confirm that the channel types for that module are all present and correct.

Page 30 - Changing the Module Mode

Page 30 QTS-CLX-APACS March 2015 Assigning ControlLogix addresses Select Tools/Auto-allocate CLX Addressing to map the APACS IOBUS data to Control

Page 31 - QTS-CLX-APACS Page 25

QTS-CLX-APACS Page 31 Diagnostic Counters QTS-CLX-APACS diagnostic counters are integers and are mapped to ControlLogix input data of type INT on co

Page 32

Page 32 QTS-CLX-APACS March 2015 TIP If the ControlLogix loses communication with the QTS-CLX-APACS, it sets the first four bytes of connection 0

Page 33 - Master Mode Operation

QTS-CLX-APACS Page 33 Enter the Module Name. It can be up to 15 characters long. It should follow the rules for naming ControlLogix aliases; it s

Page 34 - ClxApacsMasCfg Software

QTS-CLX-APACS MODULE OVERVIEW 1 Part Number 2 Module Features 2 Power Requirements 3 Other Requirements 3 Package Contents 3 INSTALLATION 4

Page 35 - QTS-CLX-APACS Page 29

Page 34 QTS-CLX-APACS March 2015 If the ControlLogix processor with the connection to the QTS-CLX-APACS is in run mode when you download, the fo

Page 36

QTS-CLX-APACS Page 35 The QTS-CLX-APACS Module Properties dialog box appears. It shows the required connections and the minimum connection sizes.

Page 37 - QTS-CLX-APACS Page 31

Page 36 QTS-CLX-APACS March 2015 Enter the RSLinx Path Specifier to set the location of the module. This will be the name of the second ENBT modu

Page 38

QTS-CLX-APACS Page 37 In this example, the alias is for an analog output on channel 1 of the module in rack 1 slot 6, which is mapped to ControlLogi

Page 39

Page 38 QTS-CLX-APACS March 2015 Accessing Data Required Connections In master mode, the QTS-CLX-APACS does not begin scanning the I/O bus until

Page 40

QTS-CLX-APACS Page 39 In monitor mode, the bits do not update and are always 0. Aliases to the bits are provided by the configuration tool for comp

Page 41

Page 40 QTS-CLX-APACS March 2015 Troubleshooting ControlLogix Module LEDs The module has three status LEDs to indicate the state of internal opera

Page 42

QTS-CLX-APACS Page 41 OK LED – Module Health The OK LED indicates module health. A red LED indicates that module startup diagnostics have failed or

Page 43

Page 42 QTS-CLX-APACS March 2015 If the module has no configuration, it refuses connection requests from the ControlLogix processor and returns a

Page 44 - Accessing Data

QTS-CLX-APACS Page 43 for the bit associated with the module in rack 1 slot 4. Use the aliases to access the status bits. TIP If the ControlLogix lo

Page 45 - QTS-CLX-APACS Page 39

QTS-CLX-APACS Page iii Saving a Configuration File 21 Uploading and Downloading Configurations 21 Configuring the QTS-CLX-APACS Module in RSLogix

Page 46 - Troubleshooting

Page 44 QTS-CLX-APACS March 2015 Updating the Firmware The module firmware is updated using either of the two configuration programs. Copy the new

Page 47 - RSLogix 5000

QTS-CLX-APACS Page 45 Specifications QTS-CLX-APACS ControlLogix Module Parameter Specification Module Location ControlLogix chassis Function Co

Page 48 - Slot Status Bits

Page 46 QTS-CLX-APACS March 2015 Support How to Contact Us: Sales and Support Sales and Technical Support for this product are provided by ProSof

Page 49 - Fatal Errors

QTS-CLX-APACS Page 47 Warranty Quest Technical Solutions warrants its products to be free from defects in workmanship or material under normal use a

Page 50 - Updating the Firmware

Page iv QTS-CLX-APACS March 2015 Program/Run 38 Diagnostic Data 38 TROUBLESHOOTING 40 ControlLogix Module LEDs 40 NET LED – IOBUS Status 40 C

Page 51 - Specifications

QTS-CLX-APACS Module Overview The QTS-CLX-APACS connects a ControlLogix controller to an APACS® IOBUS network. Use the QTS-CLX-APACS

Page 52 - Support

Page 2 QTS-CLX-APACS March 2015 Each I/O connection supports: • scheduled input data, 496 SINTs or 124 REALs • scheduled output data, 496 SINTs

Page 53 - Warranty

QTS-CLX-APACS Page 3 Watchdog and Jabber Inhibit A watchdog timer is implemented in the module’s hardware. If the firmware does not kick the watchdo

Comments to this Manuals