S3964R ProLinx Gateway Configure the Gateway
Siemens 3964R Protocol Driver Manual
Page 16 of 64 ProSoft Technology, Inc.
April 14, 2009
2.1.2 [3964R Port x]
This section defines the port configuration for the 3964R device.
Enable
Yes or No
This parameter specifies whether to enable or disable the port. No = Port
Disabled, Yes = Port Enabled.
RS Interface
0 = RS-232
1 = RS-422
2 = RS-485
This parameter is only used for Ports 1, 2, or 3 to configure the electrical
interface for the individual ports.
Important: This parameter should not be used for port 0. Use the jumper on the back of the
module to select the RS interface for Port 0.
Baud Rate
300 to 115200
This parameter specifies the baud rate to be used on the port. Valid values are
300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, and 115200.