Configuring your RLXIC-EV RLXIC-EV Intelligent Cellular
User Manual RadioLinx® Intelligent Cellular Ethernet Gateway for Verizon
ProSoft Technology, Inc. Page 85 of 104
March 10, 2010
On the other side, if the server receives an out of sequence packet, it will
send a message to the device noting the missing sequence and the RLXIC-
EV will retransmit.
Simple Reliable Mode - The RLXIC-EV will 'give up' after a configured
number, *PPMAXRETRIES, of attempts and discard messages that cannot
be transmitted or received after that number of tries.
The acknowledgment message is the ASCII string "UDPACK" followed by the
sequence number.
UDP Sequence Reliable - A sequence number is prepended to the report
packet in a range of 0c30 to 0x7f inclusive. The sequence number is ASCII
readable, allowing test tools to acknowledge the packets.
The acknowledgment message is the ASCII string "SEQACK" followed by the
sequence number.
The sequence number is not stored and will be reinitialized to 0x30 when the
RLXIC-EV is reset or power cycled. If a message packet is not acknowledged
within the specified number of retries, the packet and its contents will be
dropped.
TCP Sequence Reliable - The same as UDP Sequence Reliable but using
TCP instead of UDP.
TCP Listen Reliable - TCP Listen reliable is same as TCP Sequence
Reliable except the Reports Server must initiate the connection before the
RLXIC-EV will send reports. This allows servers to by-pass some firewalls.
5.12 I/O Configuration
This group includes configuration commands for the digital and analog inputs and
relay and digital outputs as applicable to a specific device. Some of the values
shown as a part of this group are not changeable but reflect the current status.
Only those devices with available inputs and outputs will display this group.
Please refer to the Hardware Users Guide, in the Inputs, Relay Outputs, and
Power Status chapter, for more information on the basic features of the I/O
settings.
Note: The I/O configuration options and displayed status of the I/O depends on the RLXIC-EV.